A.AC20氣氛控制器------可取代原MMI馬拉松的CARB-PC

B.9200溫度和氣氛控制器---可取代原MMI馬拉松的CARB-PRO+10PRO

C.7EK 溫度控制表

D.O2SENSOR-------可完全和MMI馬拉松的O2SENSOR相容

E.WINCARB電腦軟體----MMI馬拉松的控制表和SSI的控制表都可使用

F.WINCPC電腦軟體-----MMI馬拉松的控制表和SSI的控制表都可使用

G.三氣分析儀

H.露點計

GOLD PROBE / CARBON SENSOR 

 

 

 

 

 

 

Accuracy:
•3rd generation - delivers precision and repeatability in a variety of controlled atmosphere heat treating processes

Compatibility:
•Totally interchangeable with other manufacturers' probes and instrumentation

Return on Investment:
•Low priced with a full one year warranty on both the original and the rebuilt probe

Cemet coating:
•Impenetrable layer extends probe sheath life in the harshest applications and reduces the catalytic effect between nickel and methane

Optimum burnout efficiency
•Patented sheath/electrode design facilitates probe burnout, promoting longer life

Rebuild Policy
•SSi's Gold Probe can be rebuilt one time after the initial warranty period has expired for 50% of the original cost. Rebuilt warranty is an additional 12 months

Specifications

%Carbon:

0.01% to 1.6%

Temperature:

- 1100°F to 2000°F

Mounting

1" NPT

Impedance:

Less than 10k ohms

 

Insertion Length

Standard

18.6" (473 mm)

Plus 750

27.7" (704 mm)

Plus 900

33.0" (838 mm)

Plus 1000

37.25" (946 mm)

Fixed Hub Option:

Add 1.5" (38.1mm)
insertion

•"Standard" sheath on the top
•"Open" sheath on the bottom

 

                                     科盟實業股份有限公司    Marstate

 Atmosphere / Temperature Controllers 

 



AC20 Single-loop Atmosphere Controller  

 

 

 

 

 

 

 

 

 

 

  (P/N 31069) 1/4 DIN, Relay /4-20mA Control Output / Events

The AC20 controller is designed to control both endothermic generators and atmosphere furnaces. To accomplish both, the AC20 can display and control on three units of measure: % Carbon, Dew Point or probe millivolts. In addition, Probe resistance, probe temperature, COF, H2F and probe recovery can be displayed.

• Simple to configure, simple to operate
• Designed specifically for atmosphere control
• Functions well on batch or continuous furnaces and endothermic generators
• 1/4 DIN, % Carbon, Dew Point, O2 Millivolts
• Internal timers for burn-out / probe maintenance
• On-board probe diagnostics
• Events: 8 IN - 10 OUT
• RS485, Modbus Communication protocol
• Ships pre-configured per your specifications
• Programmable when interfaced wtih SSi's eSPP

                                     科盟實業股份有限公司    Marstate

 SSi's PGA3000 Portable 3-Gas NDIR Analyzer

Measured Gases:
 • Carbon Monoxide (CO) - Range (0 - 100%)
 • Carbon Dioxide (CO2) - Range (0 - 2.000%)
 • Methane (CH4) - Range (0 - 100%)
 • PLUS % Oxygen (O2) - Range (0.1 - 25.0%)


• On-board datalogging (500 minutes for 10 units)
• Utility software included to transfer data to a PC

Operating Manual

Specifications

Method of sampling:

Extraction by internal sampling pump through filter

Data Retrieval:

5000 minutes

 

 

Calibration:

Factory or field

Zero and Span drift:

< 1% of full scale

Probe carbon prediction:

Requires manual input of probe mV's and temperature

Speed of response:

Approximately 30 seconds to 90% step change

Output:

COF and Pf calculation

Digital communications:

RS232 port for ModBus®

Ambient temperature range:

0 - 125 F. (0 - 50 C.)

Flow meter

0 - 2 SCFH

Power:

115/230 VAC 50/60 Hz, Battery Powered (12 hrs)

Size and weight:

16"H X 20"L X 8"D, Approximately 30 lbs

 

                                    科盟實業股份有限公司    Marstate 

SSi's Single Gas Analyzers 

CO (Carbon Monoxide) - Range: 0.00 - 100.00%
CO2 (Carbon Dioxide) - Range: 0.000 - 2.000%, 0.00 - 15.00%
CH4 (Natural Gas (Methane)) - Range: 0.00 - 100.0%
O2 (Oxygen) - Range: 0.0 - 25.0%

Operating Manual

Specifications

Standard Range:

0 to 80 F. (-18 to 27 C.)

Display:

Digital

 

 

Accuracy and Repeatability:

+/- 1 F.

Operating Temperature Range:

0 to 120 F. (-15 to 49 C.)

Power:

115/240 VAC 60 Hz

Resolution:

+/- 1 F

Zero and Span Drift:

+/- 1 F. Maximum

Digital Communications:

RS485 (ModBus)

Control Output: 4 - 20mA

4 - 20mA

 

                                    科盟實業股份有限公司    Marstate

Model DPC3500 - Continuous Low Range Dew Point Analyzer

• Dew Point ranges from 20 to -148 °F. (-7 to -100°C.)
• Measures Dew Point in Hydrocarbon Fuels
  and Plant Air Systems
• Specifically suited for Hydrogen/Nitrogen applications

  • Integral sample pump and filters
 • LED Digital Readout

Operating Manual

Specifications

Standard Range:

-148 to 20 F. (-100 to -7 C.)

Display:

Digital

 

 

Accuracy and Repeatability:

+/- 1 F.

Operating Temperature Range:

0 to 120 F. (-15 to 49 C.)

Power:

115/240 VAC 60 Hz

Resolution:

+/- 1 F

Zero and Span Drift:

+/- 1 F. Maximum

Digital Communications:

RS485 (ModBus)

Control Output: 4 - 20mA

4 - 20mA

 

                                                                                                                                                      科盟實業股份有限公司    Marstate
Model DPC3500 - Typical Sample Filtering System
 